− | + | == Nvidia Tesla T4 == | |
1. Remove power from the server; | 1. Remove power from the server; | ||
Строка 43: | Строка 43: | ||
7. Press "F10" button (Save and exit). | 7. Press "F10" button (Save and exit). | ||
− | + | == Nvidia Quadro P620 == | |
1. Without installing graphics accelerators apply power to the server; | 1. Without installing graphics accelerators apply power to the server; |
Текущая версия на 11:24, 15 октября 2024
Содержание
Preface
This manual has been tested for the following types and families of GPU accelerators:
- Nvidia Tesla T4 – simultaneous operation of 3 accelerators on the motherboard;
- Nvidia Quadro P620 – simultaneous operation of 4 accelerators on the motherboard.
Procedure for launching graphics accelerators
Nvidia Tesla T4
1. Remove power from the server;
2. Install graphics accelerators in the PCIe x16 slots of the motherboard (x8 with the ability to install x16 expansion cards in them);
3. Apply power to the server;
4. Wait for the image to appear on the screen. Hold down the "ESC" key and wait to enter the BIOS menu;
5. Go to Setup Utility -> Advance -> Socket Configuration -> Common RefCode Configuration;
6. Make settings as shown below; the values of the first three functions are required and the rest are default:
Common RefCode Configuration | ||
---|---|---|
1 | MMCFG | 512M |
2 | MMIO High Base | 56T |
3 | MMIO High Granularity Size | 1024G |
4 | Isoc Mode | Auto |
5 | Numa | Enabled |
6 | Publish SRAT | Enabled |
7 | SRAT Memory Hot Plug | Disabled |
8 | SRAT CPU Hot Plug | Disabled |
7. Press "F10" button (Save and exit).
Nvidia Quadro P620
1. Without installing graphics accelerators apply power to the server;
2. Wait for the image to appear on the screen. Hold down the "ESC" key and wait to enter the BIOS menu;
3. Go to Setup Utility -> Advance -> Video Configuration;
4. Set Display Mode option to the "On Board First" state;
5. Press "F10" button (Save and exit);
6. Wait until the server restarts (the changes will take effect). Remove power from the server;
7. Install graphics accelerators in the PCIe x16 slots of the motherboard (x8 with the ability to install x16 expansion cards in them);
8. Apply power to the server;
9. Wait for the image to appear on the screen. Hold down the "ESC" key and wait to enter the BIOS menu;
10. Go to Setup Utility -> Advance -> Socket Configuration -> Common RefCode Configuration;
11. Make settings as shown below; the values of the first three functions are required and the rest are default:
Common RefCode Configuration | ||
---|---|---|
1 | MMCFG | 64M |
2 | MMIO High Base | 56T |
3 | MMIO High Granularity Size | 1G |
4 | Isoc Mode | Auto |
5 | Numa | Enabled |
6 | Publish SRAT | Enabled |
7 | SRAT Memory Hot Plug | Disabled |
8 | SRAT CPU Hot Plug | Disabled |
12. Press "F10" button (Save and exit)