= Procedure for launching graphics accelerators =
 
= Procedure for launching graphics accelerators =
  
'''Nvidia Tesla T4'''
+
== Nvidia Tesla T4 ==
  
 
1. Remove power from the server;
 
1. Remove power from the server;
Строка 40: Строка 40:
 
| 8 || SRAT CPU Hot Plug || Disabled
 
| 8 || SRAT CPU Hot Plug || Disabled
 
|}
 
|}
 +
 +
7. Press "F10" button (Save and exit).
 +
 +
== Nvidia Quadro P620 ==
 +
 +
1. Without installing graphics accelerators apply power to the server;
 +
 +
2. Wait for the image to appear on the screen. Hold down the "ESC" key and wait to enter the BIOS menu;
 +
 +
3. Go to Setup Utility -> Advance -> Video Configuration;
 +
 +
4. Set Display Mode option to the "On Board First" state;
 +
 +
5. Press "F10" button (Save and exit);
 +
 +
6. Wait until the server restarts (the changes will take effect). Remove power from the server;
 +
 +
7. Install graphics accelerators in the PCIe x16 slots of the motherboard (x8 with the ability to install x16 expansion cards in them);
 +
 +
8. Apply power to the server;
 +
 +
9. Wait for the image to appear on the screen. Hold down the "ESC" key and wait to enter the BIOS menu;
 +
 +
10. Go to Setup Utility -> Advance -> Socket Configuration -> Common RefCode Configuration;
 +
 +
11. Make settings as shown below; the values ​​of the first three functions are required and the rest are default:
 +
{| class="wikitable"
 +
|-
 +
!  !! '''Common RefCode Configuration'''
 +
|-
 +
| 1 || '''MMCFG''' || '''''64M'''''
 +
|-
 +
| 2 || '''MMIO High Base''' || '''''56T'''''
 +
|-
 +
| 3 || '''MMIO High Granularity Size''' || '''''1G'''''
 +
|-
 +
| 4 || Isoc Mode || Auto
 +
|-
 +
| 5 || Numa || Enabled
 +
|-
 +
| 6 || Publish SRAT || Enabled
 +
|-
 +
| 7 || SRAT Memory Hot Plug || Disabled
 +
|-
 +
| 8 || SRAT CPU Hot Plug || Disabled
 +
|}
 +
 +
12. Press "F10" button (Save and exit)

Текущая версия на 11:24, 15 октября 2024

Preface

This manual has been tested for the following types and families of GPU accelerators:

  • Nvidia Tesla T4 – simultaneous operation of 3 accelerators on the motherboard;
  • Nvidia Quadro P620 – simultaneous operation of 4 accelerators on the motherboard.

Procedure for launching graphics accelerators

Nvidia Tesla T4

1. Remove power from the server;

2. Install graphics accelerators in the PCIe x16 slots of the motherboard (x8 with the ability to install x16 expansion cards in them);

3. Apply power to the server;

4. Wait for the image to appear on the screen. Hold down the "ESC" key and wait to enter the BIOS menu;

5. Go to Setup Utility -> Advance -> Socket Configuration -> Common RefCode Configuration;

6. Make settings as shown below; the values ​​of the first three functions are required and the rest are default:

Common RefCode Configuration
1 MMCFG 512M
2 MMIO High Base 56T
3 MMIO High Granularity Size 1024G
4 Isoc Mode Auto
5 Numa Enabled
6 Publish SRAT Enabled
7 SRAT Memory Hot Plug Disabled
8 SRAT CPU Hot Plug Disabled

7. Press "F10" button (Save and exit).

Nvidia Quadro P620

1. Without installing graphics accelerators apply power to the server;

2. Wait for the image to appear on the screen. Hold down the "ESC" key and wait to enter the BIOS menu;

3. Go to Setup Utility -> Advance -> Video Configuration;

4. Set Display Mode option to the "On Board First" state;

5. Press "F10" button (Save and exit);

6. Wait until the server restarts (the changes will take effect). Remove power from the server;

7. Install graphics accelerators in the PCIe x16 slots of the motherboard (x8 with the ability to install x16 expansion cards in them);

8. Apply power to the server;

9. Wait for the image to appear on the screen. Hold down the "ESC" key and wait to enter the BIOS menu;

10. Go to Setup Utility -> Advance -> Socket Configuration -> Common RefCode Configuration;

11. Make settings as shown below; the values ​​of the first three functions are required and the rest are default:

Common RefCode Configuration
1 MMCFG 64M
2 MMIO High Base 56T
3 MMIO High Granularity Size 1G
4 Isoc Mode Auto
5 Numa Enabled
6 Publish SRAT Enabled
7 SRAT Memory Hot Plug Disabled
8 SRAT CPU Hot Plug Disabled

12. Press "F10" button (Save and exit)